Sliding wear behaviour of Zr-ion-implanted D3 tool steel


SAKLAKOĞLU N., SAKLAKOĞLU İ. E., Ceyhun V., Monteiro O., Brown I.

Tribology International, vol.40, no.5, pp.794-799, 2007 (SCI-Expanded, Scopus) identifier identifier

  • Publication Type: Article / Article
  • Volume: 40 Issue: 5
  • Publication Date: 2007
  • Doi Number: 10.1016/j.triboint.2006.07.004
  • Journal Name: Tribology International
  • Journal Indexes: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Page Numbers: pp.794-799
  • Keywords: tribology, wear, metal-vapour vacuum arc, stainless steels, Zr-ion implantation, tool steel
  • Manisa Celal Bayar University Affiliated: Yes

Abstract

The wear and friction characteristics of zirconium-ion-implanted AISI D3 tool steel have been investigated using pin-on-disc methods. Ion implantation was carried out using a vacuum-arc-based ion implanter to form multicharged zirconium ion beams at a mean ion energy of 130 keV, and the implantation doses investigated were approximately 3.6×1016, 5×1016 and 1×1017 ions cm-2. It was found that Zr implantation decreased both the wear and the coefficient of friction. The beneficial effects of Zr implantation in terms of associated Auger electron spectroscopy, Rutherford backscattering spectroscopy and scanning electron microscopy microprobe analyses are described. © 2006 Elsevier Ltd. All rights reserved.