Evaluation of the performance of a strengthened scaled masonry structure using experimental methods
Structures, cilt.91, 2026 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 91
- Basım Tarihi: 2026
- Doi Numarası: 10.1016/j.istruc.2026.112674
- Dergi Adı: Structures
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
- Anahtar Kelimeler: Ambient vibration test, Capacity curve, CFRP application, Masonry structure, Scaled vault
- Manisa Celal Bayar Üniversitesi Adresli: Evet
Özet
Historical masonry structures present numerous uncertainties due to variations in materials, construction techniques, damage accumulated over the years, and reinforcement applications. These factors all make it more complex to determine structural behavior. Experimental studies conducted both in situ and in laboratory environments play a crucial role in reducing and clarifying these uncertainties. In this study, a scaled barrel vault supported by arches in two directions and by main walls was constructed using conventional techniques in a laboratory. The structure, with dimensions of 3.91 m × 1.96 m × 1.84 m, was tested using both destructive and non-destructive methods following a defined test chronology. Thus, the structural responses of the complex system were comprehensively evaluated. In the destructive tests, an incremental horizontal loading was applied to the structure under three different conditions: unreinforced, reinforced with wooden tie members, and reinforced with CFRP. From these tests, the capacity curves and damage patterns, along with their distribution across different regions of the structure, were obtained. In the non-destructive tests, ambient vibration measurements were performed to determine the natural frequencies of the masonry vault under four alternative conditions: unreinforced, with additional mass, in a damaged state, and reinforced with CFRP. Additionally, the contribution of the tie members was evaluated under each of these four primary conditions. The results indicate that strengthening the damaged masonry structure helps prevent or delay crack formation while enhancing stiffness, displacement capacity, and energy absorption capacity. In addition, the initial stiffness of the masonry structure exhibits a strong correlation with changes in natural frequency values.