Effect of slice step size on prediction of natural vibration properties of bone tissue


ALTINTAŞ G.

Mathematical and Computational Applications, cilt.17, sa.3, ss.235-243, 2012 (Scopus) identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 17 Sayı: 3
  • Basım Tarihi: 2012
  • Doi Numarası: 10.3390/mca17030235
  • Dergi Adı: Mathematical and Computational Applications
  • Derginin Tarandığı İndeksler: Scopus, TR DİZİN (ULAKBİM)
  • Sayfa Sayıları: ss.235-243
  • Anahtar Kelimeler: Bone tissue, Modal analysis, Slice step size, Slice thickness, Voxel size
  • Manisa Celal Bayar Üniversitesi Adresli: Evet

Özet

Several vibration analysis procedures are used for determination of the level of bone loss, status of implant stability, modal damping factor and numerous other properties of tissues. The detection methods of bone properties are to compare the results of theoretical work with practical results. So, there are many options for processing of image data and establishing the finite element (FE) model that differentiation of calculated outputs is inevitable. Uncertainty of outputs can lead to mistakes while mechanical parameters or behaviors of tissue are determined. In this study, the effect of Micro-CT scanning intensity in connection with the reconstruction process on properties of the modal behavior of bone tissue were investigated. Results have shown that examined parameters have important effects on numerical values of the natural frequencies and modal behaviors. Furthermore, it has been revealed that numerical values and mode shapes must be considered together for properly understanding the natural vibration analysis of bone tissue.