Effects of sinusoidal-shaped vortex promoters and inclined nano-enriched magnetic field on the cooling and ANN-based optimization of two conductive panels mounted in a T-shaped channel
Journal of Thermal Analysis and Calorimetry, vol.151, no.17, pp.14721-14742, 2026 (SCI-Expanded, Scopus)
- Publication Type: Article / Article
- Volume: 151 Issue: 17
- Publication Date: 2026
- Doi Number: 10.1007/s10973-026-16008-y
- Journal Name: Journal of Thermal Analysis and Calorimetry
- Journal Indexes: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Aerospace Database, Chemical Abstracts Core, Chimica, Compendex, Index Islamicus, INSPEC, Academic Search Ultimate (EBSCO), Engineering Source (EBSCO), Materials Science & Engineering Collection (ProQuest), Technology Collection (ProQuest)
- Page Numbers: pp.14721-14742
- Keywords: ANN, Double panels, Finite volume method, Sinusoidal baffle, T-shaped cooling
- Manisa Celal Bayar University Affiliated: Yes
Abstract
The current work proposes a novel cooling system for two conductive panels using a T-shaped channel with sinusoidal wavy vortex promoters under nano-enriched magnetic field effects. A finite volume method is used to analyze the influence of Reynolds number (Re=50–300), magnetic field strength (Ha=0–50), magnetic field inclination angle (γ=0–90∘), vortex promoter amplitude (Af= 0–0.2), and wave number (Nf= 1–5) on the cooling performance of the panels. Two different cooling systems are used as Conf-1 and Conf-2. The vortex size is controlled by the Re and magnetic field parameters, while in the Conf-2 cooling system, a vortex develops near the right junction. At the maximum Re, Conf-2 provides a 2.9∘C reduction in temperature for the horizontal panel, but leads to a 4.4∘C increase in temperature for the vertical panel compared to Conf-1. At maximum strength of magnetic field, the upper panel temperature increases by 13.2∘C in Conf-1 and 1.2∘C in Conf-2, while in the lower vertical panel it decreases by 1.3∘C in Conf-1 but increases by 8.5∘C in Conf-2. From the lowest to the highest inclination angle, the upper panel temperature changes by +5.9∘C (Conf-1) and -4∘C (Conf-2), whereas the lower panel varies by +0.1∘C and −5.2∘C, respectively. The cooling performance of each panel is profoundly influenced by the amplitude and wave number of the wavy baffle, but the extent of temperature reduction depends on the cooling configuration. A model based on artificial neural network (ANN) predicts the average surface temperatures of each panel as functions of Re and magnetic field parameters which enables identification of optimal cooling conditions; under these optima, sinusoidal baffle significantly lowers temperatures, achieving up to 67∘C reduction for horizontal Panel in Conf-2 and up to 35∘C in Conf-1 cooling system.